Rigorous Highly Accelerated Life Testing (HALT) prevented telecommunications company from a complete product recall.
Challenge
HALT Testing is a highly aggressive temperature and vibration cycling process which is used very early in the design stage of the product life cycle.
A major telecoms company were performing a series of various tests on a complex and high-value product, which consisted of several large plug-in cards secured to a large backplane. Initially, extensive design verification testing was performed to qualify and validate the product. No problems or failures were found during this test process. Afterward, several complete units were sent to external sites for alpha/beta testing. This type of evaluation lasted for several months and was completed successfully without any failures.
Solution
The next stage was the final qualification where the product was subjected to HALT at the STERIS test laboratory. During the fast ramp temperature excursions from the Upper Operating Limit (UOL) to the Lower Operating Limit (LOL), failures started to occur causing major functional errors.
Failure analysis found that an inner layer etch was defective, opening and closing like an electronic switch. This failure was caused by a manufacturing error in the backplane and exposed by HALT during the high to low-temperature fast ramp rates causing the inner layer etch to expand and contract. When the product was brought back to ambient temperature it performed correctly.
Results
The result was a major engineering change on several hundred backplanes. If the product had not been exposed to a HALT, it would have been shipped with the latent defect and possibly resulting in immediate field failures a total product recall. The company subsequently acknowledged that the testing could have saved millions of dollars.
Related TechTips
A Guide to Determining the Most Appropriate Distribution Simulation for a Medical or Pharmaceutical Device
Introduction The packaging of sterile medical and pharmaceutical devices needs to ensure that the product shall function as intended and remain sterile to the point of use, from both a patient safety and regulatory requirement perspective. As part of p
Bacterial Endotoxin Testing
Pyrogens are substances that can induce a fever response in the body, and sources can be either microbial or non-microbial. The focus of this TechTip is the testing associated with a microbial pyrogen, bacterial endotoxin. Bacterial endotoxins are memb
Biological Indicator Population Verification Test
Purpose In a sterilization process where biological indicator (BI) sterility results are used as part of product release criteria, the BIs shall be procured from an approved supplier with a minimum population of test organisms defined. The population o
Screening for Adverse and Inhibitory Substances
Test method validation for adverse and/or inhibitory substances is important to ensure that the measurement of contamination on a device is not impacted by substances present in the test. Adverse substances and/or inhibitory substances (e.g. antimicrob